• Proportional Output for X and Y Directions with independent adjustmets

  • Adjustable trip angles and time delays for both X and Y axes- Significantly reduces the prototype phase

  • Dual trip point capability - Provides an extended capability without adding a second sensor to the system

  • Normally on or normally off versions

  • Optional Bubble level Available - Provides visual reference to the horizon

  • Viscously damped pendulum - Eliminates inadvertent outputs due to momentary movement

  • Reverse polarity and short circuit protection - Needs no fuse, cannot be damaged by electrical mishap


  • Electrical

    Supply Voltage 6 VDC
    Output Range 3 VDC neutral, ± 1.8 VDC swing
    Idle Current Draw Current at 6 VDC: 20 mADC
    Accuracy Full Signal: ±.6° (adjustable gain)
    Protection Reverse Polarity, Over-Voltage, Open/Shorted Signal Leads, Transient Voltage Supply
    Hysteresis 0.3°

    Environmental

    Operating Temperature -40 - 70 degrees (C)
    Protection Sealed Epoxy Potting (black)
    Resistance Humidity, Water/Rain, Sun/UV Exposure